I. Objectives

Bone marrow puncture is a core invasive procedure in hematology and clinical medicine at large, possessing both diagnostic value and therapeutic significance.

1. Diagnostic Role

By aspirating bone marrow fluid, multi-dimensional and multi-level laboratory analyses can be performed to provide critical pathophysiological information for clinical decision-making:

Diagnostic Dimension

Specific Tests

Clinical Significance

Cytomorphology​

Bone marrow cellularity, proportional distribution and morphological changes of each cell lineage

Foundation for classifying and diagnosing hematological disorders

Cytogenetics​

Karyotype analysis (e.g., Philadelphia chromosome, 5q− deletion)

Prognostic stratification in leukemia and myelodysplastic syndromes

Molecular Biology​

Gene mutation detection (e.g., JAK2 V617F, FLT3-ITD, NPM1)

Precise diagnosis, targeted therapy guidance, and minimal residual disease monitoring

Hematopoietic Function​

Hematopoietic stem cell culture (CFU-GM, BFU-E, etc.)

Assessment of hematopoietic reserve capacity

Pathogen Detection​

Parasite smears (malaria parasites, Leishmania-Donovan bodies), bacterial culture (e.g., Salmonella typhi)

Definitive diagnosis of infectious diseases

Metabolic Disorders​

Identification of specific cells (e.g., Gaucher cells, Niemann-Pick cells)

Diagnostic gold standard for certain rare diseases

2. Therapeutic Role

Therapeutic Monitoring and Prognosis: Dynamic evaluation of treatment response in hematological diseases, providing evidence for regimen adjustment.

Bone Marrow Transplantation: Providing a sufficient and qualified volume of hematopoietic stem cells for allogeneic or autologous transplantation.


II. Indications

The indications for bone marrow puncture are extensive, covering the entire continuum from initial diagnostic workup to end-stage treatment evaluation:

Hematological Disorders: Diagnosis and differential diagnosis of various anemias, leukemias, lymphomas, multiple myeloma, myelodysplastic syndromes (MDS), and myeloproliferative neoplasms (MPN); assessment of whether systemic malignancies have invaded or metastasized to the bone marrow.

Unexplained Symptom Complexes: Unexplained hepatosplenomegaly or lymphadenopathy, and fever of unknown origin (FUO) undiagnosed by routine laboratory tests.

Infectious Diseases: Bone marrow culture serves as the "last line of defense" for typhoid and paratyphoid fever (with significantly higher positivity rates than blood culture); parasitological confirmation of malaria and kala-azar (visceral leishmaniasis) via smear examination.

Metabolic and Genetic Disorders: Gaucher disease - the identification of Gaucher cells on bone marrow smear is the gold standard for definitive diagnosis; Niemann-Pick disease, etc.

Treatment Response Assessment: Dynamic monitoring of bone marrow suppression severity and recovery following chemotherapy or targeted therapy for hematological malignancies.

Hematopoietic Stem Cell Transplantation: Collection of a sufficient number of CD34⁺ hematopoietic stem cells for transplantation.


III. Contraindications

The contraindications for bone marrow puncture are extremely limited, reflecting the high safety profile of this procedure. However, the following situations require a careful risk-benefit assessment:

Contraindication Type

Specific Condition

Clinical Consideration

Absolute (relative)​

Hemophilia and severe coagulation dysfunction​

If bone marrow examination is not the sole diagnostic modality, the procedure is strictly prohibited​ to prevent uncontrollable delayed local hemorrhage

Relative​

Local skin infection at the puncture site​

An alternative puncture site must be selected; if all feasible sites are infected, infection control should be prioritized or the procedure performed with caution after weighing risks and benefits

⚠️ Critical Clarification: Thrombocytopenia alone is NOT a contraindication for bone marrow puncture.​ For patients with immune thrombocytopenia (ITP) or leukemia-induced thrombocytopenia, the procedure can still be performed safely with adequate manual compression for hemostasis. This understanding is crucial for clinical decision-making - many beginners unnecessarily delay essential bone marrow examination due to excessive fear of bleeding.


IV. Pre-Operative Preparation

4.1 Patient Preparation

Step

Specific Content

Purpose

Coagulation screening

For patients suspected of coagulation abnormalities, pre-procedure testing of PT, APTT, TT, FIB, and platelet count

Assess bleeding risk; determine whether correction is needed before the procedure

Informed consent

Explain the purpose, procedure, possible discomfort, and precautions to the patient/family

Respect patient autonomy, build trust, reduce anxiety

Cooperation guidance

Inform the patient of a brief sharp pain during aspiration; instruct to report discomfort promptly; advise keeping the puncture site dry and clean for 3 days post-procedure

Improve compliance and reduce infection risk

Documentation

Obtain signed informed consent for bone marrow puncture

Ensure legal compliance and medical safety

Communication Tip: Pre-operative communication should not be a mere formality. It is essential to inform the patient in advance that "a brief sharp pain during aspiration is normal,"preventing sudden patient movement due to fear that could lead to needle deviation or accidental injury.

4.2 Material Preparation

Standard Equipment Checklist on the Procedure Cart:

Category

Item Details

Bone marrow puncture pack​ (sterile)

Bone marrow aspiration needle (with stylet), sterile tray, forceps, fenestrated drape, gauze, cotton balls

Disinfection supplies​

2.5% iodine tincture, 75% alcohol, 0.5% povidone-iodine (alternative)

Anesthetic agent​

2% lidocaine, 5 ml

Other consumables​

Disposable syringes (5 ml and 10 ml), sterile gloves, clean glass slides, spreader slide, EDTA anticoagulation tubes (if flow cytometry or genetic testing is planned)

4.3 Operator Preparation

Patient identification: Strictly perform the "three checks and seven verifications" to confirm patient name, medical record number, and intended puncture site.

Knowledge base: Thoroughly understand the indications, contraindications, procedural steps, and complication management for bone marrow puncture.

Clinical assessment: Review the patient's underlying condition, coagulation status, and history of previous punctures.

Positioning: Assist the patient into the correct position, palpate and mark the selected puncture site with a skin marker.

Aseptic preparation: Perform seven-step hand hygiene, wear a cap and surgical mask.

Smear competency: Be capable of preparing qualified and standardized bone marrow smears according to the diagnostic purpose - a terminal step often overlooked by beginners but critically important.


V. Procedural Steps

5.1 Patient Positioning

The choice of position depends on the anatomical location of the selected puncture site:

Puncture Site

Recommended Position

Anatomical Rationale

Posterior superior iliac spine​

Prone or lateral decubitus (with knees flexed in lateral position)

Bony landmark is prominent, facilitating localization and stabilization

Anterior superior iliac spine​

Supine

Convenient for the operator; high patient comfort

Sternum​

Supine, with a thin pillow under the shoulders to slightly elevate the thorax

Exposes the sternal body for controlled needle angulation

Lumbar spinous process​

Sitting (leaning forward with knees drawn up) or lateral decubitus

Spinous process is prominent, but the operative field is more limited

5.2 Puncture Site Selection - Strategy and Priority

Puncture Site

Localization Method

Advantages

Limitations

Posterior superior iliac spine​ (First choice)

A rounded bony prominence ~3 cm lateral to the L5–S1 interspace level

Abundant marrow, thin cortical bone, safe (no vital organs deep to the site), high success rate; preferred site for bone marrow harvest in transplantation

Patient must be repositioned; slightly more complex positioning

Anterior superior iliac spine​

Flat bony surface 1–2 cm posterior to the anterior superior iliac spine

Easy to stabilize, convenient operation, no risk to major vessels/nerves

Marrow quality slightly inferior to posterior site; multiple aspirations may be needed

Sternum​

Midline of the sternal body at the 2nd intercostal space (below the sternal angle)

Extremely rich in marrow, highly hematopoietic; mandatory for aplastic anemia workup

In close proximity to the heart and great vessels; highest risk; depth must be strictly controlled

Lumbar spinous process​

Tip of the corresponding lumbar spinous process

Good marrow quality

Technically difficult; requires high patient cooperation; rarely a first-choice site

Localization Principle: The puncture site must avoid any local skin infection. Once determined, mark it clearly with a skin marker to prevent loss of reference after draping.

5.3 Disinfection and Draping

Step

Operational Details

Key Points

Gloving

Operator dons sterile gloves using aseptic technique

Ensures全程 (entire procedure) sterility

Prep

Place cotton balls in two separate basins; pour 2.5% iodine tincture and 75% alcohol respectively

Use separately to avoid cross-contamination

Iodine application

Starting at the puncture site and moving outward in a spiral, disinfect with a diameter >15 cm; allow 1 minute for air-drying

Iodine tincture requires sufficient contact time for bactericidal effect

Alcohol de-iodination

Using the same spiral technique, wipe with 75% alcohol for two passes to thoroughly remove iodine residue

Prevents skin irritation from residual iodine and interference with smear staining

Draping

Center the fenestrated drape over the puncture site

In sitting/lateral position, secure the drape to the patient's clothing with tape to prevent slippage

5.4 Anesthesia - "Anesthetize an Area, Not Just a Point"

The core technique of anesthesia lies in multi-point periosteal infiltration - this is the key determinant of the patient's pain experience:

Wheal formation: Draw 2% lidocaine into a 5 ml syringe; inject subcutaneously at the puncture site to form a skin wheal.

Layered infiltration: Advance the needle perpendicularly, aspirating intermittently (to confirm no blood return), and inject anesthetic while withdrawing, infiltrating the subcutaneous tissue, fascia, and periosteum layer by layer.

Periosteal anesthesia (critical step): Once the needle tip contacts the periosteum, keep it perpendicular and perform multi-point fan-shaped injections across the periosteal surface centered on the puncture point​ - i.e., "anesthetize an area" rather than just the needle entry point. This effectively prevents periosteal stretch pain caused by any mismatch between the puncture and anesthetic sites.

Depth recording: When the anesthetic needle touches the periosteum, note the depth of insertion to guide subsequent adjustment of the aspiration needle length.

5.5 Puncture - The Technical Core

(1) Needle Length Adjustment

Perform a "needle comparison"​ between the aspiration needle and the anesthetic needle: adjust the depth stop so that the aspiration needle tip extends 0.5–1.0 cm beyond​ the depth at which the anesthetic needle reached the periosteum.

Puncture Site

Distance from Depth Stop to Needle Tip

Anatomical Basis

Posterior/Anterior superior iliac spine

~1.5 cm

Iliac cortical bone is relatively thick; deeper entry into the medullary cavity is required

Sternum / Lumbar spinous process

~1.0 cm

Sternal cortex is thin but overlies great vessels; spinous process bone is dense

(2) Puncture Technique - Site-Specific Variations

Posterior/Anterior Superior Iliac Spine Puncture:

Fix the skin at the puncture site between the left thumb and index finger.

Hold the aspiration needle in the right hand and insert it perpendicular to the bone surface.

Once the needle tip contacts bone, rotate it along its long axis (like turning a screw)​ to slowly penetrate the cortex.

When a sudden loss of resistance ("pop")​ is felt, the needle tip has entered the marrow cavity.

Insertion depth: approximately 1 cm​ beyond the periosteum.

⚠️ Prohibited Actions: During the procedure, never swing the needle body widely or force it forward violently​ - these are the primary causes of needle breakage.

Sternal Puncture (High-Risk Procedure - Exercise Extreme Caution):

Left hand fixation; right hand holds the needle with the bevel facing the marrow cavity and the needle tip directed toward the patient's head.

Insert at an angle of 70°–80°​ to the sternal surface (NOT perpendicular!).

Advance slowly with rotational motion; depth controlled at 0.5–1.0 cm.

Typically, there is NO distinct loss of resistance; rely on depth control and tactile feedback.

For elderly patients with osteoporosis or those with multiple myeloma, the initial force must be exceptionally gentle.

Lumbar Spinous Process Puncture:

Insert perpendicular to the bone surface, advance slowly with rotation; depth 0.5–1.0 cm.

Usually no typical loss of resistance; rely on depth control.

(3) Aspiration - The Critical Moment of Success

Withdraw the stylet and place it on the sterile tray.

Attach a dry 10 ml syringe​ (dryness is critical - moisture will cause the marrow sample to clot or alter cell morphology).

Aspirate until bone marrow fluid appears (approximately 0.2–0.5 ml is sufficient; over-aspiration must be avoided​ - excessive peripheral blood dilution compromises cytomorphological evaluation).

Advance warning to the patient: A brief sharp pain​ during aspiration is normal; informing the patient beforehand prevents sudden movement due to fear.

Managing Aspiration Failure: If no marrow fluid is obtained, reinsert the stylet, rotate slightly or advance another 0.1–0.2 cm, then reattach the syringe and aspirate again. Avoid repeated large adjustments.

5.6 Smear Preparation - The Terminal Step That Determines Diagnostic Quality

Step

Key Points

Common Errors

Needle withdrawal

Immediately reinsert the stylet after aspiration to prevent marrow fluid loss along the track

Forgetting to reinsert the stylet, resulting in sample loss

Smearing

Quickly place a drop of marrow fluid on a glass slide; the assistant spreads it at a 30°–45° angle using a spreader slide

Delay causes clotting; uneven distribution

Number of slides

Prepare 5–8 smears routinely; additional slides may be needed based on testing requirements

Insufficient slides for simultaneous multi-test analysis

Quality standard

A qualified smear should have a distinct head, body, and tail, with even cell distribution and a feathered edge at the tail

Smear too thick/thin, cell clumping, uneven distribution

Labeling

Mark with patient name, gender, age, medical record number, and puncture date

Missing information leading to sample confusion

Smear Thickness Adjustment Principle:

Markedly hypercellular marrow​ (e.g., chronic myeloid leukemia): Smears should be thinner​ to prevent excessive cell overlap that interferes with differential counting.

Hypocellular or severely hypocellular marrow​ (e.g., aplastic anemia): Smears should be thicker​ to ensure scattered hematopoietic cells can be identified.

5.7 Needle Removal and Post-Procedure Care

Needle removal: Reinsert the stylet and withdraw the needle smoothly along the insertion axis.

Hemostasis: Cover the puncture site with sterile gauze; the operator or assistant should apply continuous manual pressure for 1–3 minutes​ (1 minute is usually sufficient for patients with normal coagulation; extend to >5 minutes for those with coagulation abnormalities).

Dressing: Secure the gauze with adhesive tape; instruct the patient/family to keep the puncture site dry and avoid water exposure for 3 days.

Sample transport: Send smears for immediate processing (to prevent cell autolysis); gently invert anticoagulation tubes 4–5 times before sending to the laboratory.


VI. Complications and Management

6.1 Perforation of the Posterior Sternal Cortex - The Most Dangerous Complication

Item

Detailed Information

Mechanism​

Excessive force or over-advancement penetrates the posterior sternal plate, injuring the heart or great vessels in the mediastinum

High-risk populations​

Elderly patients with osteoporosis; multiple myeloma patients (severe bone destruction, extremely thin cortex)

Preventive measures​

① Strictly set the depth stop at 1 cm from the needle tip; ② Use a 70°–80° insertion angle; ③ Apply minimal initial force with slow rotation; ④ Consider iliac crest puncture first for high-risk patients

Emergency management​

Immediate needle withdrawal and local compression; if signs of cardiac tamponade or massive hemorrhage appear, urgent cardiothoracic surgery consultation is required, with possible emergency thoracotomy

6.2 Needle Breakage - Caused by Operator Error

Item

Detailed Information

Mechanism​

① Excessive needle swing after the tip enters the bone; ② Violent forced advancement when encountering dense bone

Preventive measures​

① Maintain needle stability throughout the procedure; avoid side-to-side rocking; ② Never force advancement against dense bone - consider changing the puncture site or using a larger-caliber needle

Management​

Keep the patient's position unchanged to prevent migration of the broken fragment; consult orthopedics or surgery for removal, which may require an operative procedure


VII. Objective Criteria for Successful Bone Marrow Puncture

Criterion

Specific Manifestation

Clinical Significance

Aspiration pain​

Patient experiences a brief sharp pain at the moment of aspiration

Confirms needle tip is within the marrow cavity; negative pressure stimulates endosteal nerves

Marrow particles​

Pale yellow, sand-like granules visible in the aspirated fluid

Confirms the sample originates from marrow parenchyma, not peripheral blood dilution

Characteristic cells​

Smear reveals megakaryocytes, plasma cells, reticulum cells, tissue basophils, and other marrow-specific cells​

Gold standard - confirms the specimen is qualified marrow fluid, ruling out "dry tap" or peripheral blood contamination

Recognition and Management of "Dry Tap": If no marrow fluid can be aspirated despite multiple adjustments, and the smear shows only peripheral blood components, consider the following possibilities: ① Myelofibrosis; ② Extensive malignant marrow infiltration (e.g., metastatic carcinoma); ③ Extreme leukemic cell hypercellularity causing viscous marrow; ④ Technical factors. In such cases, integrate peripheral blood smear findings, bone marrow biopsy (using a trephine biopsy needle), and imaging studies for comprehensive evaluation.


Appendix: Bone Marrow Puncture Procedure Checklist

Phase

Check Item

✓

Pre-op​

Coagulation status assessed

 
 

Informed consent signed

 
 

Puncture site marked

 
 

All materials ready (puncture pack, anesthetic, slides, etc.)

 

Intra-op​

Disinfection diameter >15 cm; draping standardized

 
 

Anesthesia reaches periosteum with multi-point infiltration

 
 

Needle depth correctly adjusted

 
 

Aspiration volume 0.2–0.5 ml; smears prepared promptly

 

Post-op​

Adequate compression hemostasis

 
 

Dressing secured; post-op instructions given

 
 

Slides properly labeled; samples sent to lab promptly

 