Disposable
video
Disposable

Disposable Epidural Tuohy Cannula

Product Specification Product Show Operation Procedure: 1. Place the patient in the same lumbar position 2. The puncture point was L2-3 or L3-4. 3. Puncture method Epidural or epidural block is required for the aseptic procedure. After successful epidural puncture, a 25G lumbar puncture needle...

Description

Product Specification

Product name

Disposable Epidural Tuohy Cannula

Material

Stainless steel, NiTi, etc.

PropertiesInjection & Puncture Instrument
Needle Size14G, 15G, 16G, 17G, 18G, 19G, 20G, 21G, 22G, 23G, 24G, 25G, 26G, 27G
Needle Length2"–6" lengths Custom sizes available upon request.
TypeQuincke Point or Pencil Point

Custom feature

According to your 2D/3D Drawing or sample provided

Package

Standard carton or according to customer's requirement

Product Show

Operation Procedure:

1. Place the patient in the same lumbar position

2. The puncture point was L2-3 or L3-4.

3. Puncture method

Epidural or epidural block is required for the aseptic procedure. After successful epidural puncture, a 25G lumbar puncture needle was inserted into the needle under the guidance of the epidural puncture needle, and the arachnoid membrane was punctured to exit the needle core. Cerebrospinal fluid was seen to flow out of the needle. 2-3ml local anesthetic for lumbar anesthesia was randomly injected, and the lumbar puncture needle was withdrawn. The epidural catheter was inserted through the epidural puncture needle (3cm through the needle opening). The epidural puncture needle was withdrawn, and the puncture point was covered with sterilized gauze to fix the catheter. After helping the patient turn supine, measure the block level of lumbar anesthesia. After injection of 3-5ml local anesthetic through the epidural catheter, the operation can be started without signs of high block plane after 5 minutes. During the operation, appropriate amount of local anesthetic was injected through the epidural catheter as needed to maintain anesthesia.

4. Due to the injection of light or heavy local anesthetics into the subarachnoid space, it still needs a period of time for epidural operation, which is bound to cause significant block on one side of the limb and poor on the other side and affect the whole block effect. Therefore, it is recommended to use local anesthetic with equal specific gravity when combined block.

517


447-1452-1

516518

Our Factory

needle factory

Production Department

Production Department

Production Process

Needle Production Process

Checkout Room

Checkout Room

Packing

packing1

Our Certification

certificate

Shipping

shipping

Disposable Epidural Tuohy Cannula

20

Hot Tags: disposable epidural tuohy cannula, China, suppliers, manufacturers, factory, customized, custom, cheap, low price, made in China

(0/10)

clearall