Zero-Fluoroscopy Access
Oct 13, 2026
Guide (Continued)
Step 4: Cross Under Echo. Use ultrasound to confirm the position of the needle tip. When the tip is in contact with the septum and the position looks correct, activate the RF generator for a short burst. Watch the impedance reading to confirm that the tissue is being penetrated. Advance the needle smoothly after the RF burst, using the curve to guide the tip into the left atrium.
Step 5: Reserve Fluoroscopy for Troubleshooting, Not Routine Access. The goal is zero fluoroscopy, but this does not mean that fluoroscopy is never used. If the procedure is not progressing as expected, or if there is any doubt about the position of the needle, fluoroscopy can be used as a troubleshooting tool. The key is that fluoroscopy should be the exception, not the rule.
Step 6: Confirm Access with Pressure or Contrast. After the needle crosses the septum, confirm that the tip is in the left atrium. Inject a small amount of contrast dye and observe its flow under ultrasound, or use pressure monitoring to confirm the left atrial pressure waveform.
Experience
Green EP labs-labs that have committed to zero-fluoroscopy procedures-show that zero-fluoro transseptal is teachable when the needle is forgiving. The curved RF needle is forgiving because it provides tactile feedback that helps the operator navigate without visual confirmation.
One important lesson from the field: the learning curve for zero-fluoroscopy access is longer than the learning curve for the curved RF needle itself. Operators must learn to trust their tactile sense and the ultrasound image, rather than relying on fluoroscopy. This takes time and practice.
Another lesson: the curved RF needle is particularly well-suited for zero-fluoroscopy procedures because the curve provides a consistent approach angle. The operator does not need to "hunt" for the target with torque and rotation. The curve guides the tip along the natural path, reducing the need for visual confirmation.
Teams that have adopted zero-fluoroscopy access report several benefits. First, radiation exposure is dramatically reduced for both patient and staff. Second, procedure times are often shorter because the operator does not need to pause for fluoroscopy images. Third, the procedures are more comfortable for the patient, who is not exposed to the noise and heat of the fluoroscopy machine.
Summary
The future of cardiac access is image-guided, not radiation-dependent. The Curved Tip RF Puncture Needle, combined with ultrasound guidance and 3D mapping, enables truly zero-fluoroscopy access procedures. This is better for the patient, better for the staff, and better for the hospital.
The curved RF needle is the key enabler of this shift. The curve provides tactile direction, the RF provides controlled penetration, and the combination allows the operator to perform access procedures with confidence and precision, without the need for ionizing radiation.
Recommendation
For hospitals and EP labs considering the adoption of zero-fluoroscopy access, the following recommendations are offered.
Procure Needles with Clear Echo Markers. The needle tip should be visible under ultrasound. Choose a needle with a clear echo marker that makes it easy to see on the echo image.
Standardized Hub Colors. Use standardized hub colors to help operators quickly identify the needle type and size. This reduces the risk of using the wrong needle for the procedure.
Train Fellows in Echo-First Access. The next generation of electrophysiologists should be trained in echo-first access from the beginning. This will make zero-fluoroscopy procedures the norm rather than the exception.